SPECIFICATIONS: F6222
Application Standard
Relative Core Power Reading (dB) +5 to -40
Insertion Loss (dB) (250µm, 1310/1550) < 0.6 / <3.0
Detector Sensitivity (dBm, 1550 nm) -40
Fiber Type Singlemode, 8-10µm core, 250 µm clear Acrylate coating
Spectral Response (nm) 850 to 1700
Optical Test Tone Detection 270 Hz, 1kHz and 2kHz
Minimum Fiber Slack 0.75” (19mm)
Power One 9V Alkaline Battery
Battery Life 5,000 operations
Operating Temperature -20 to +50°C
Storage Temperature -40 to +60°C
Humidity 0 to 90% non-condensing
Dimensions (HWD) 7.75” x 1.25” x 1.0” (197 x 32 x 25mm)
Weight 8.0 oz (227g)
The Wilcom Model F6222 Telecom Optical Fiber Identifier is a rugged, easy-to-use installation and maintenance instrument which identifies optical fibers by detecting the optical signals being transmitted through a fiber. By utilizing local detection technology (non-destructive macro-bend detection which does not damage or overstress the fiber), this units eliminates the need to open the fiber at the splice point for identification; eliminating the probability of interrupting service.

This Optical Fiber Identifier detects low frequency tones at 270 Hz, 1000 Hz and 2000 Hz. When traffic is present on the fiber under test, an audible tone can be heard as well as the traffic direction which is indicated by LEDs illuminating on the probe.

Buying, Selling, Trading Wilcom F6222C

During installations, maintenance, rerouting, or restorations it is often necessary to isolate a specific fiber without disrupting service. A light source such as Wilcom’s Model FS1316 used in conjunction with the Optical Fiber Identifiers can make the job a lot easier.

This Optical Fiber Identifier includes a carrying pouch containing three easy to use field interchangeable adapter heads to accommodate; 900 µm buffered fiber, ribbon or 250µm coated fiber and 3mm jacketed fiber.

Features

Rugged Metal Case

The OFI unit uses the same field proven lightweight rugged metal housing as the rest of Wilcom’s Optical Fiber Identifier product line.

850nm to 1700nm Range

With the use of InGaAs detectors, the unit can be used on singlemode and multimode applications.

Audible Tone

The unit provides an audible tone in the presence of a fiber optic signal.

Core Power Display

Both the F6222 OFI, and F6222C OFI can display Relative Core Power which is helpful in identifying bad connectors, splice points, etc.

LED Indication

LEDs indicate tone detection, Traffic presence, Traffic Direction, and Low Battery.

Hands-Free-Operation

With an easy to use thumb lock, hands-free operation can be enabled and disabled.

Includes:

Wilcom F6222 OFI Probe
900µm Foam Covered Adapter
250µm/Rib Foam Perimeter Adapter
3mm Slotted Adapter
User Manual On CD-ROM
Carrying Case

If you’re selling your Wilcom F6222C please fill out form on the right hand side of page.

Selling Wilcom F6230 – We Buy New F6230 (‘s) Top Dollar Paid!

If you’re looking to Sell Wilcom F6230 Optical Fault Locator OFL

Hand-Held, Visible Light Source
Singlemode or Multimode Fiber
FC, ST or SC Connectors
F6230 Class II Laser 670nm Visible
F6231 Class II Laser 635nm

Buying, Selling, Trading Wilcom F6230

Includes:

  • Wilcom F6230 Optical Fault Locator
  • Hard Copy User Manual
  • Hard Carrying Case

If you’re selling your Wilcom F6230 please fill out form on the right hand side of page.

Selling Wilcom F6121 – We Buy New F6121 (‘s) Top Dollar Paid!

If you’re looking to Sell Wilcom F6121 Optical Fiber Identifier OFI Probe

The Wilcom Model F6121 Basic Optical Fiber Identifier is a rugged, easy-to-use installation and maintenance instrument which identifies optical fibers by detecting the optical signals being transmitted through a fiber. By utilizing local detection technology (non-destructive macro-bend detection which does not damage or overstress the fiber), the unit eliminates the need to open the fiber at the splice point for identification; eliminating the probability of interrupting service.

The Optical Fiber Identifier detects low frequency tones at 270 Hz, 1000 Hz and 2000 Hz. When traffic is present on the fiber under test, an audible tone can be heard as well as the traffic direction which is indicated by LEDs illuminating on the probe.

Buying, Selling, Trading Wilcom F6121

During installations, maintenance, rerouting, or restorations it is often necessary to isolate a specific fiber without disrupting service. A light source such as Wilcom’s Model FS1316 used in conjunction with the Optical Fiber Identifier can make the job a lot easier.

The Optical Fiber Identifier includes a carrying pouch containing three easy to use field interchangeable adapter heads to accommodate; 900 µm buffered fiber, ribbon or 250µm coated fiber and 3mm jacketed fiber.

If you’re selling your Wilcom F6121 please fill out form on the right hand side of page.

Selling Wilcom F6121A – We Buy New F6121A (‘s) Top Dollar Paid!

If you’re looking to Sell Wilcom F6121A Optical Fiber Identifier OFI Probe

SPECIFICATIONS: F6121A
Application Basic
Relative Core Power Reading (dB) None
Insertion Loss (dB) (250µm, 1310/1550) < 0.6 / <3.0
Detector Sensitivity (dBm, 1550 nm) -40
Fiber Type Singlemode, 8-10µm core, 250 µm clear Acrylate coating
Spectral Response (nm) 850 to 1700
Optical Test Tone Detection 270 Hz, 1kHz and 2kHz
Minimum Fiber Slack 0.75” (19mm)
Power One 9V Alkaline Battery
Battery Life 5,000 operations
Operating Temperature -20 to +50°C
Storage Temperature -40 to +60°C
Humidity 0 to 90% non-condensing
Dimensions (HWD) 7.75” x 1.25” x 1.0” (197 x 32 x 25mm)
Weight 8.0 oz (227g)

The Wilcom Model F6121A Basic Optical Fiber Identifier is a rugged, easy-to-use installation and maintenance instrument which identifies optical fibers by detecting the optical signals being transmitted through a fiber. By utilizing local detection technology (non-destructive macro-bend detection which does not damage or overstress the fiber), the unit eliminates the need to open the fiber at the splice point for identification; eliminating the probability of interrupting service.

The Optical Fiber Identifier detects low frequency tones at 270 Hz, 1000 Hz and 2000 Hz. When traffic is present on the fiber under test, an audible tone can be heard as well as the traffic direction which is indicated by LEDs illuminating on the probe.

During installations, maintenance, rerouting, or restorations it is often necessary to isolate a specific fiber without disrupting service. A light source such as Wilcom’s Model FS1316 used in conjunction with the OpticalFiber Identifier can make the job a lot easier.

The Optical Fiber Identifier includes a carrying pouch containing three easy to use field interchangeable adapter heads to accommodate; 900 µm buffered fiber, ribbon or 250µm coated fiber and 3mm jacketed fiber.

Buying, Selling, Trading Wilcom F6121A

Features:

Rugged Metal Case
The F6121A OFI uses the same field proven lightweight rugged metal housing as the rest of Wilcom’s Optical Fiber Identifier product line.

850nm to 1700nm Range
With the use of InGaAs detectors, the unit can be used on singlemode and multimode applications.

Audible Tone
The unit provides an audible tone in the presence of a fiber optic signal.

Tone Detection
The F6121A OFI can detect 270Hz, 1kHz and 2kHz tones for easy fiber cable identification

LED Indication
LEDs indicate tone detection, Traffic presence, Traffic Direction, and Low Battery.

Hands-Free-Operation
With an easy to use thumb lock, hands-free operation can be enabled and disabled.

If you’re selling your Wilcom F6121A please fill out form on the right hand side of page.

Selling Wilcom F6222 – We Buy New F6222 (‘s) Top Dollar Paid!

If you’re looking to Sell Wilcom F6222 Telecom Optical Fiber Identifier OFI

SPECIFICATIONS: F6222
Application Standard
Relative Core Power Reading (dB) +5 to -40
Insertion Loss (dB) (250µm, 1310/1550) < 0.6 / <3.0
Detector Sensitivity (dBm, 1550 nm) -40
Fiber Type Singlemode, 8-10µm core, 250 µm clear Acrylate coating
Spectral Response (nm) 850 to 1700
Optical Test Tone Detection 270 Hz, 1kHz and 2kHz
Minimum Fiber Slack 0.75” (19mm)
Power One 9V Alkaline Battery
Battery Life 5,000 operations
Operating Temperature -20 to +50°C
Storage Temperature -40 to +60°C
Humidity 0 to 90% non-condensing
Dimensions (HWD) 7.75” x 1.25” x 1.0” (197 x 32 x 25mm)
Weight 8.0 oz (227g)
The Wilcom Model F6222 Telecom Optical Fiber Identifier is a rugged, easy-to-use installation and maintenance instrument which identifies optical fibers by detecting the optical signals being transmitted through a fiber. By utilizing local detection technology (non-destructive macro-bend detection which does not damage or overstress the fiber), this units eliminates the need to open the fiber at the splice point for identification; eliminating the probability of interrupting service.

This Optical Fiber Identifier detects low frequency tones at 270 Hz, 1000 Hz and 2000 Hz. When traffic is present on the fiber under test, an audible tone can be heard as well as the traffic direction which is indicated by LEDs illuminating on the probe.

Buying, Selling, Trading Wilcom F6222

During installations, maintenance, rerouting, or restorations it is often necessary to isolate a specific fiber without disrupting service. A light source such as Wilcom’s Model FS1316 used in conjunction with the Optical Fiber Identifiers can make the job a lot easier.

This Optical Fiber Identifier includes a carrying pouch containing three easy to use field interchangeable adapter heads to accommodate; 900 µm buffered fiber, ribbon or 250µm coated fiber and 3mm jacketed fiber.

Features

Rugged Metal Case

The OFI unit uses the same field proven lightweight rugged metal housing as the rest of Wilcom’s Optical Fiber Identifier product line.

850nm to 1700nm Range

With the use of InGaAs detectors, the unit can be used on singlemode and multimode applications.

Audible Tone

The unit provides an audible tone in the presence of a fiber optic signal.

Core Power Display

Both the F6222 OFI, and F6222C OFI can display Relative Core Power which is helpful in identifying bad connectors, splice points, etc.

LED Indication

LEDs indicate tone detection, Traffic presence, Traffic Direction, and Low Battery.

Hands-Free-Operation

With an easy to use thumb lock, hands-free operation can be enabled and disabled.

Includes:

Wilcom F6222 OFI Probe
900µm Foam Covered Adapter
250µm/Rib Foam Perimeter Adapter
3mm Slotted Adapter
User Manual On CD-ROM
Carrying Case

If you’re selling your Wilcom F6222 please fill out form on the right hand side of page.